Floor-mounted and walk-in chemical fume hoods for heavy-duty processes

Floor-Standing & Walk-In Fume Hoods

A floor-standing fume hood — floor-mounted fume hood — carries the chemistry that will not fit on a bench: tall condenser trains, pilot reactors, drum-scale additions, electroplating cells. The chamber stands on its own full-height base, the sash rises to give working access at torso height, and the exhaust system scales to the larger volume of air the enclosure sweeps. WSHLAB floor-standing hoods come in the three ducted materials — 1.0mm cold-rolled all-steel, welded 5-8mm polypropylene for acid digestion and perchloric acid service, and brushed stainless steel for clean and food-grade work — each in 1200, 1500 and 1800mm widths, with exhaust volumes up to 1843 m³/h and a vertical tempered glass sash over the full working face. Where the process grows past the sash opening, walk-in fume hood configurations take over: the chamber floor opens to the room and the enclosure walks around the apparatus. Tell us the tallest assembly and the chemistry, and we will specify the form, material and exhaust schedule.

  • 3Products
  • 0Direct categories
  • Technical support
Floor-Standing & Walk-In Fume Hoods

Showing all 3 results

  • All-Steel Floor-Standing Fume Hood

    Model series
    T1 / T3 / T5 / T6 floor-standing
    Working widths
    1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
    Overall dimensions
    1200/1500/1800 × 850 × 2350mm (full height with base)
    Body
    1.0mm cold-rolled steel, epoxy powder coated
    Price on request
  • PP Floor-Standing Fume Hood

    Model series
    P1 floor-standing
    Working widths
    1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
    Overall dimensions
    1200/1500/1800 × 850 × 2350mm (full height with base)
    Body
    5-8mm welded polypropylene (PP)
    Price on request
  • Stainless Steel Floor-Standing Fume Hood

    Model series
    Stainless floor-standing (201 / 304 / 316)
    Working widths
    1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
    Overall dimensions
    1200/1500/1800 × 850 × 2350mm (full height with base)
    Body
    201/304/316 stainless steel, brushed
    Price on request

TECHNICAL DATA

Engineering the floor-standing series

The floor platform welds the full aerodynamic package to a heavy-gauge base: the 1.0-1.2mm steel or 5-8mm PP chamber over a reinforced base cabinet with chemical-resistant worktop, the sash running full-face on the synchronous counterweight, and a plenum sized for the larger exhaust. Adjustable feet level the cabinet on imperfect floors; service chases route gas, water and power without opening the chamber.

Floor-Standing & Walk-In Fume Hoods

Stainless Steel Floor-Standing Fume Hood

View Product
Model series
Stainless floor-standing (201 / 304 / 316)
Working widths
1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
Overall dimensions
1200/1500/1800 × 850 × 2350mm (full height with base)
Body
201/304/316 stainless steel, brushed
Liner
304 stainless steel
Baffle
304 stainless, three-section
Sash
5mm tempered glass, vertical rising, synchronous belt counterweight
Base cabinet
Full-height stainless, reinforced
Lighting
LED, Shadow-Free LED
Electrical
LCD control panel, splash-proof sockets
Exhaust volume
1065 m³/h (1200mm) · 1397 m³/h (1500mm) · 1729 m³/h (1800mm)
Face velocity
0.4-0.6 m/s at the working opening
Width
1200mm · 1500mm · 1800mm
Material
Stainless Steel 304
Form Factor
Floor-Standing
Sash Type
Vertical Tempered Glass

Applications

Where floor-standing hoods work

Chemical capture where the process outgrows the bench.

Perchloric acid digests with washdown-ready PP surfaces

Pilot reactors and small-scale process development

Electroplating and surface treatment cells

Industrial QC and corrosion testing at line scale

PERFORMANCE & SELECTION

What is a floor-mounted fume hood?

A floor-standing fume hood is a ducted chemical hood whose chamber extends to the floor, either with an integral base cabinet (the standard floor model) or as an open walk-in enclosure around floor-scale apparatus. The aerodynamics are the same as any hood — airfoil sill, three-section baffle, uniform face velocity — scaled to a taller chamber and a bigger exhaust volume.

  • Chamber extends to the floor on an integral base
  • Walk-in configurations for floor-scale apparatus
  • Sash at torso height with full working access
  • Exhaust volumes up to 1843 m³/h
What is a floor-mounted fume hood?
CONFIGURATION & COMPATIBILITY

Materials for heavy-duty service

Heavy-duty does not change the material logic; it raises the stakes. All-steel floor hoods take the general purpose load: solvents, reagents, distillation. PP floor hoods are the acid digestion fume hood of record — perchloric acid work included, with no metal in the airstream. Stainless floor hoods carry industrial QC, food and cleanroom work with a wipe-down 304 chamber. All three share the sash hardware, baffles and service options.

  • All-steel: general purpose and solvent chemistry at scale
  • PP: acid digestion and perchloric acid fume hood service
  • Stainless 304: industrial, food and cleanroom duty
  • Worktops: ceramic, epoxy resin, phenolic or stainless
Materials for heavy-duty service
IDENTIFICATION & TRACEABILITY

Clear Product Identification & Specification

Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.

  • Product and model identification
  • Option-specific SKU information
  • Consistent quotation specifications
PRODUCT IDENTIFICATIONFloor-Standing & Walk-In Fume Hoods
Catalog
Laboratory equipment
Products
3
Selection
Specification-led
Traceability

Traceability and documentation

Floor-scale hoods ship with mechanical coordination documents.

  • Serialised chamber, base, sash and electrical records
  • Exhaust and duct schedules for mechanical design
  • Material certificates for stainless and PP bodies
  • Load ratings for base cabinets and worktops
  • O&M manual with commissioning checklist
Traceability and documentation
Quality system

Quality system and factory testing

Floor hoods are assembled, levelled and airflow-mapped before dispatch.

G—01

ISO 9001 production line with CE conformity

G—02

Face velocity verified at multiple sash heights

G—03

SEFA 1 construction; ASHRAE 110 method on request

G—04

Base cabinet load and door alignment checks

G—05

Serialised factory test report with each hood

Why WSHLab

Why laboratories choose WSHLAB floor hoods

Bench hood aerodynamics, floor-scale capacity.

All-steel, PP and stainless bodies to 1800mm widths

Walk-in configurations quoted from your apparatus drawings

Exhaust volumes up to 1843 m³/h with matched fan packages

Full-height base cabinets with chemical-resistant worktops

Same sash, baffle and liner hardware as the benchtop series

Contact Our Supply Team
OPTIONS & SPECIFICATIONS

Floor-Standing & Walk-In Fume Hoods Options & Specifications

Choose the format that suits your application, workload and handling requirements.

Floor-standing (floor-mounted) and walk-in fume hoods

All-steel, PP and stainless steel 304 bodies

High exhaust volume up to 1843 m³/h

Tall apparatus: condenser trains, pilot reactors, drums

Full-height base cabinets with chemical-resistant worktops

TypeCapacity / OptionMaterial / SpecificationSuitable ApplicationStorage / Handling
Floor-standing (floor-mounted) and walk-in fume hoodsBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
All-steel, PP and stainless steel 304 bodiesBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
High exhaust volume up to 1843 m³/hBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
Tall apparatus: condenser trains, pilot reactors, drumsBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
Full-height base cabinets with chemical-resistant worktopsBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
Delivery and site

Delivery and installation

Floor hoods deliver knock-down and assemble in place.

  1. 01

    Knock-down panels pass any doorway and stairwell

  2. 02

    Level floor, 220V/50Hz supply, anchor points

  3. 03

    30-50 cm service clearance behind for duct and services

  4. 04

    Duct, fan and stack packages quoted with the hood

  5. 05

    Commissioning certification and training available; 12-month warranty

Delivery and installation
VIDEOS

Manufacturing & Quality Process

Category video library

Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.

TECHNICAL RESOURCES

Related Articles & Technical Resources

October 29, 2026

What to Include in a Laboratory Product Quote

Read More
October 29, 2026

A Practical Guide to Laboratory Glassware

Read More
October 29, 2026

How to Choose a Benchtop Centrifuge

Read More
QUESTIONS & ANSWERS

Floor-Standing & Walk-In Fume Hoods: frequently asked questions

The questions buyers ask most often when specifying Floor-Standing & Walk-In Fume Hoods, answered by our technical team.

Walk-in available?

Yes — where apparatus is taller than the sash, walk-in configurations enclose it with the chamber floor as the laboratory floor. Quoted from your apparatus drawings.

What materials?

All-steel for general purpose, welded PP for acid digestion and perchloric acid, brushed stainless 304 for clean, food and industrial service.

What exhaust volume?

1036-1684 m³/h (all-steel, PP) and 1065-1729 m³/h (stainless) by width; walk-in hoods are engineered to the open area. Fan and duct packages quoted with the hood.

Is it suitable for heavy-duty work?

Yes — reinforced base cabinets, chemical-resistant worktops and high exhaust volumes are designed in, not added on.

Get a quotation

Request your floor-standing fume hood quotation

Send the apparatus dimensions, the chemistry and the room layout — we return the hood form, material and exhaust schedule with pricing within one working day.