Fume Hood Filters & Accessories
A fume hood is a system, and systems consume parts. Filters load and expire; sashes cloud, chip and break; fans wear; monitors drift. The WSHLAB filters and accessories range keeps the hoods above running: replacement filtration media for every ductless cabinet in the range, sash and baffle hardware for the ducted series, exhaust fans and blowers to the published volumes, and the airflow instrumentation that proves the containment. The filter list is the deep one: HEPA H13 and H14 and ULPA U15 particulate grades; activated carbon for the general solvent load; impregnated media for acid gases, ammonia and formaldehyde; VOC-optimised beds for the ductless cabinets. All of them are stocked spares for the WSHLAB ductless range and sized for common third-party cabinets too. Everything is quote-configured: tell us the hood model and the chemistry (or the serial number) and we will match the filter set, the fan curve or the sash glass, and quote the parts that fit — the first time.
- 0Products
- 0Direct categories
- Technical support
Products are being specified
Send your technical requirement for a tailored quotation.
Request a quoteWhat the parts keep running
Every fume hood, BSC and ductless cabinet in the range.
Sash glass and hardware replacement after service life or damage
Fan and damper replacement on exhaust systems
Worktop and liner refurbishment on service life
Airflow monitoring for certification and daily checks
HEPA and ULPA filters
Particulate grades run from HEPA H13 (99.95% at MPPS) through H14 (99.995%) to ULPA U15 (99.9995%) — the filter classes that turn a cabinet's airflow into clean air. They serve the BSC downflows, the ductless cabinet polish stages and any enclosure where particles are the load. Sizes are stocked for the WSHLAB range and cut to order for third-party cabinets.
- HEPA H13: 99.95% efficiency at MPPS
- HEPA H14: 99.995%
- ULPA U15: 99.9995%
- Stocked for WSHLAB cabinets; custom sizes to order
Carbon and chemical filters
Gas-phase filtration is chosen by chemistry: general activated carbon for the solvent spectrum; impregnated media for acid gases (SOx, HCl, HF families), ammonia and amines, and formaldehyde; VOC-optimised beds for the ductless cabinet range. Every media is documented against the chemical compatibility chart, so the filter you order is the filter your chemistry needs — and the saturation alarm on the cabinet tells you when its life is over.
- Activated carbon for the general solvent load
- Acid gas media: SOx / HCl / HF families
- Ammonia and amine media
- Formaldehyde media; VOC-optimised beds
- Compatibility chart documented for every media
Clear Product Identification & Specification
Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.
- Product and model identification
- Option-specific SKU information
- Consistent quotation specifications
- Catalog
- Laboratory equipment
- Products
- 0
- Selection
- Specification-led
Traceability and documentation
Parts are serialised against the hoods they serve.
- Filter batch and date records
- Glass and hardware serialisation
- Fan performance curves on file
- Change records logged against cabinet controllers
Quality system
Consumables get the same discipline as cabinets.
ISO 9001 production line with CE conformity where applicable
Filter leak tests and dating on every batch
Tempered glass certification on file
Instrument calibration traceability
Why buy the parts from the hood maker
Matched, serialised, documented — the first time.
Every part matched to the hood model and serial number
Filters documented against the chemical compatibility chart
Fans selected to the published exhaust volumes
Instruments supplied with calibration traceability
One supplier for the hood and everything it consumes
Fume Hood Filters & Accessories Options & Specifications
Choose the format that suits your application, workload and handling requirements.
HEPA H13 / H14 and ULPA U15 replacement filters
Activated carbon, acid gas, ammonia, formaldehyde and VOC filters
Sash, baffle and worktop spares
Exhaust fans, blowers and duct components
Airflow monitors, sash alarms and face velocity meters
| Type | Capacity / Option | Material / Specification | Suitable Application | Storage / Handling |
|---|---|---|---|---|
| HEPA H13 / H14 and ULPA U15 replacement filters | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Activated carbon, acid gas, ammonia, formaldehyde and VOC filters | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Sash, baffle and worktop spares | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Exhaust fans, blowers and duct components | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Airflow monitors, sash alarms and face velocity meters | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
Ordering and delivery
Quote-configured against your hood's serial number.
- 01
Send the model, the serial number and the chemistry
- 02
We match and quote the parts that fit
- 03
Filters and glass ship protected; fans palletised
- 04
12-month warranty on parts
Filters, fans and accessories
Replacement filtration, exhaust hardware and monitors from the WSHLAB parts range.




Manufacturing & Quality Process
Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.
Fume Hood Filters & Accessories: frequently asked questions
The questions buyers ask most often when specifying Fume Hood Filters & Accessories, answered by our technical team.
Do you supply HEPA H14 filters?
Yes — H13, H14 and ULPA U15 grades are stocked for the WSHLAB range and cut to order for third-party cabinets.
Carbon filters for which chemicals?
General activated carbon for solvents, plus impregnated media for acid gases, ammonia/amines and formaldehyde — every media documented against the chemical compatibility chart.
Can I get a replacement sash?
Yes — 5mm tempered glass cut to size, with sash stops, locks and counterweight hardware, serialised against your hood.
Exhaust fans too?
Yes — axial, centrifugal and inline fans selected to the published hood exhaust volumes, with dampers, duct components and airflow monitors.
Request your filters and accessories quotation
List the hoods (models or serial numbers) and the parts you need — filters by chemistry, glass by size, fans by volume — and we will quote the matching set within one working day.