Ducted Fume Hoods
A ducted fume hood is the workhorse of chemical safety: room air sweeps across the open sash face, captures the vapours, aerosols and dust generated inside the chamber, and the exhaust fan carries them through ductwork to a stack or scrubber outdoors. Nothing recirculates, nothing accumulates — the contaminant load leaves the building, which is why ducted hoods remain the default for serious chemistry. WSHLAB ducted hoods cover the full material matrix. General purpose chemical fume hood work runs in 1.0mm cold-rolled all-steel with a 5mm anti-bet liner. Concentrated acid digestion and perchloric acid work runs in welded 5-8mm polypropylene — no metal in the airstream at all. Clean, food and corrosive service runs in brushed 304 stainless. Each in 1200, 1500 and 1800mm widths, with exhaust volumes from 1036 to 1843 m³/h scaled to the width, and a vertical tempered glass sash over a three-section baffle. Every ducted hood is face-velocity mapped at multiple sash heights before it ships. Tell us the chemicals, the duct run and the fan position, and we will quote the hood with the correct exhaust volume and the duct spigot to match.
- 7Products
- 3Direct categories
- Technical support
-
All-Steel Benchtop Fume Hood
- Model series
- T1 / T5 / T6 benchtop
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 1650mm (upper cabinet); optional base cabinet 1200/1500/1800 × 79…
- Body
- 1.0mm cold-rolled steel, epoxy powder coated
Price on request -
All-Steel Floor-Standing Fume Hood
- Model series
- T1 / T3 / T5 / T6 floor-standing
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 2350mm (full height with base)
- Body
- 1.0mm cold-rolled steel, epoxy powder coated
Price on request -
All-Steel Sliding Sash Fume Hood
- Model series
- T1 sliding sash
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 1650mm (benchtop configuration)
- Body
- 1.0mm cold-rolled steel, epoxy powder coated
Price on request -
PP Benchtop Fume Hood
- Model series
- P1 / P2 benchtop
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 1650mm (upper cabinet); optional PP base cabinet
- Body
- 5-8mm welded polypropylene (PP)
Price on request -
PP Floor-Standing Fume Hood
- Model series
- P1 floor-standing
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 2350mm (full height with base)
- Body
- 5-8mm welded polypropylene (PP)
Price on request -
Stainless Steel Benchtop Fume Hood
- Model series
- Stainless benchtop (201 / 304 / 316)
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 1650mm (upper cabinet)
- Body
- 201/304/316 stainless steel, brushed
Price on request -
Stainless Steel Floor-Standing Fume Hood
- Model series
- Stainless floor-standing (201 / 304 / 316)
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 2350mm (full height with base)
- Body
- 201/304/316 stainless steel, brushed
Price on request
Engineering the ducted hood series
The chamber aerodynamics define the series: an airfoil sill, a three-section rear baffle and a balanced exhaust plenum hold a uniform 0.4-0.6 m/s face velocity whether the sash is at the working height or full open. The sash runs on a synchronous belt counterweight system — smooth, single-hand operable, and lockable. Lighting is high-brightness LED behind a vapor-tight lens; service panels come off without tools, and the electrical system carries a LCD control panel with 10A splash-proof sockets.
All-Steel Sliding Sash Fume Hood
- Model series
- T1 sliding sash
- Working widths
- 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
- Overall dimensions
- 1200/1500/1800 × 850 × 1650mm (benchtop configuration)
- Body
- 1.0mm cold-rolled steel, epoxy powder coated
- Liner
- 5mm anti-bet board
- Baffle
- 5mm anti-bet board, three-section
- Sash
- 5mm tempered glass, vertical sliding, synchronous belt counterweight, sash stop + lock
- Lighting
- LED
- Electrical
- LCD control panel, 10A splash-proof sockets
- Exhaust volume
- 1036 m³/h (1200mm) · 1360.8 m³/h (1500mm) · 1684.8 m³/h (1800mm)
- Face velocity
- 0.4-0.6 m/s at the working opening
- Sash options
- Sash stop · sash lock · combination sash · horizontal sash configurations
- Width
- 1200mm · 1500mm · 1800mm
- Material
- Cold-Rolled Steel
- Form Factor
- Benchtop
- Sash Type
- Vertical Sliding Sash
Where ducted fume hoods work
Chemical capture wherever the contaminant must leave the building.
Acid digestion and wet chemistry — PP hoods for ICP/AES/AAS sample prep
Perchloric acid work — PP construction with washdown-ready surfaces
Solvent distillation — all-steel hoods with condenser access
Industrial QC — corrosion and surface prep in floor-standing hoods
Teaching labs — demonstration chemistry with full sash protection
What is a ducted fume hood?
A ducted fume hood — the classic chemical fume hood or fume cupboard — is a ventilated enclosure whose exhaust duct carries captured contaminants out of the building. A remote fan (roof-mounted or inline) pulls air through the chamber at a controlled face velocity, through the baffle and plenum, up the duct and out. Because nothing recirculates, a ducted hood tolerates high chemical loads, heat, and compounds that no filter reliably adsorbs.
- All captured contaminant is exhausted outdoors — nothing recirculates
- Face velocity 0.4-0.6 m/s held across the sash opening
- Three-section baffle sweeps floor, work zone and ceiling
- Exhaust fan, ductwork and stack sized to the hood width
Materials: all-steel, PP and stainless steel
The chemistry inside decides the material. All-steel hoods (1.0mm cold-rolled, epoxy powder coated, 5mm anti-bet liner and baffle) are the general purpose fume hood standard — durable, economical, endlessly reconfigurable. PP hoods (5-8mm welded polypropylene body, liner and baffle) put no metal in the airstream and shrug off concentrated acids and alkalis. Stainless hoods (201/304/316 brushed body, 304 interior) are the choice for cleanrooms, food labs and corrosive service that steel coating cannot survive.
- All-steel: general purpose solvent and reagent chemistry
- PP: acid digestion, perchloric acid, wet chemistry
- Stainless steel: cleanroom, food, and clean corrosive work
- Anti-bet, PP or 304 liners with matching three-section baffles
Clear Product Identification & Specification
Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.
- Product and model identification
- Option-specific SKU information
- Consistent quotation specifications
- Catalog
- Laboratory equipment
- Products
- 7
- Selection
- Specification-led
Traceability and documentation
Ducted hoods ship with the records facilities teams need.
- Serialised body, sash, liner and electrical records
- Factory airflow and containment data archived per serial number
- Material certificates for stainless and PP bodies on request
- Duct spigot and exhaust volume schedules for mechanical design
- O&M manual with baffle, sash and filter maintenance schedules
Quality system and factory testing
Every ducted hood is airflow-mapped before packing.
ISO 9001 production line with CE conformity
Face velocity verified at multiple sash heights per ASHRAE 110 method
SEFA 1 materials and finishes; SEFA 8M worksurface practice
Electrical continuity and socket polarity check on every unit
Serialised factory test report shipped with each hood
Why laboratories choose WSHLAB ducted hoods
The full material matrix on one aerodynamic platform.
All-steel, PP and stainless steel 304 in 1200/1500/1800mm
Exhaust volumes 1036-1843 m³/h published for every width
ASHRAE 110 containment verification and SEFA 1 construction
Knock-down or assembled delivery; VAV option for energy saving
Matching ductwork, fans, scrubbers and adsorption boxes available
Ducted Fume Hoods Options & Specifications
Choose the format that suits your application, workload and handling requirements.
Ducted chemical fume hoods in three materials and three widths
Exhaust volumes from 1036 to 1843 m³/h matched to hood width
ASHRAE 110 containment testing and SEFA 1 construction
Benchtop, floor-standing and sliding sash configurations
Anti-bet, PP and 304 stainless liners with three-section baffles
| Type | Capacity / Option | Material / Specification | Suitable Application | Storage / Handling |
|---|---|---|---|---|
| Ducted chemical fume hoods in three materials and three widths | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Exhaust volumes from 1036 to 1843 m³/h matched to hood width | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| ASHRAE 110 containment testing and SEFA 1 construction | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Benchtop, floor-standing and sliding sash configurations | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
| Anti-bet, PP and 304 stainless liners with three-section baffles | By selected product | Product-specific configuration | Confirm with our team | Follow product guidance |
Delivery and installation
Knock-down flat-pack for tight sites, assembled for open ones.
- 01
Knock-down construction — stairs and corridors are never the limit
- 02
Benchtop hoods: level bench or WSHLAB base cabinet, duct spigot to duct
- 03
Floor-standing hoods: level floor, 220V/50Hz, anchor and connect duct
- 04
Exhaust fan, ductwork and stack packages quoted with the hood
- 05
Commissioning airflow certification and operator training available; 12-month warranty
Ducted fume hoods installed
All-steel and PP ducted hoods across benchtop and floor-standing installations.


Manufacturing & Quality Process
Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.
Ducted Fume Hoods: frequently asked questions
The questions buyers ask most often when specifying Ducted Fume Hoods, answered by our technical team.
What materials are available?
All-steel (1.0mm cold-rolled, anti-bet liner), polypropylene PP (5-8mm welded) and stainless steel 201/304/316 — each in 1200, 1500 and 1800mm widths.
Benchtop or floor-standing?
Both. Benchtop hoods mount on the bench or a base cabinet for reagent-scale work; floor-standing hoods carry tall apparatus and larger processes with the same sash and liner hardware.
What exhaust volume does the hood need?
1036 m³/h at 1200mm, 1360 m³/h at 1500mm, 1684 m³/h at 1800mm for all-steel and PP (stainless: 1065/1397/1729). We publish the numbers so your fan and duct are engineered, not guessed.
Is it ASHRAE 110 tested?
Yes — every hood is face-velocity mapped at multiple sash heights to the ASHRAE 110 method before shipping, and construction follows SEFA 1 with EN 14175 documentation available.
Request your ducted fume hood quotation
Tell us the chemicals, the width and the duct route, and we will quote the hood, the exhaust volume and the connection schedule — within one working day.