PP Floor-Standing Fume Hood

SKU FH-PP-F-1200
Unit price · 1200mm · Polypropylene (PP) · Floor-Standing · Vertical Tempered Glass
Price on request
Final price confirmed by quotationNo online payment required
Width: 1200mm
Material: Polypropylene (PP)
Form Factor: Floor-Standing
Sash Type: Vertical Tempered Glass
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code WidthMaterialForm FactorSash Type Price Qty Cart action
FH-PP-F-1200 1200mm Polypropylene (PP) Floor-Standing Vertical Tempered Glass Price on request — Quote
FH-PP-F-1500 1500mm Polypropylene (PP) Floor-Standing Vertical Tempered Glass Price on request — Quote
FH-PP-F-1800 1800mm Polypropylene (PP) Floor-Standing Vertical Tempered Glass Price on request — Quote
Total¥0.00

Showing 1 to 3 of 3 entries

Description

Overview

The P1 floor-standing PP fume hood is the acid digestion workhorse: welded 5-8mm polypropylene from the liner to the base, a 5mm PP baffle and a tempered glass sash — an all-plastic airstream for the chemistry that eats metal hoods alive. Acid digestion, perchloric acid work and heavy wet chemistry all live here.

Floor-standing format brings batch capacity: full-height base cabinet, worktop in ceramic or PP-friendly materials, and tall apparatus room for digestion rigs and large bath work. Exhaust volumes run 1036-1684 m³/h by width through PP-compatible ductwork, and the chamber wipes down for the wash-down discipline perchloric service demands.

Perchloric acid work needs the whole system matched — hood, duct and fan without organics where deposits could form. We quote the P1 floor hood with PP duct and fan options as a package, so the containment chain is one material from sash to stack.

Key features

  • 5-8mm welded PP body. no metal, no coating in the airstream — concentrated acids and alkalis have nothing to attack
  • Acid digestion rated. mineral acid digests, etching and wet chemistry at batch scale
  • Perchloric acid configurations. wash-down-ready PP surfaces with PP duct and fan options as a matched package
  • Full-height base cabinet. chemical-resistant worktop and storage under a standing workstation
  • Tempered glass sash. 5mm vertical rising pane on the counterweighted belt drive
  • LED lighting and LCD panel. vapor-tight lighting and splash-proof controls that wipe clean
  • ASHRAE 110 verification. face velocity mapped before dispatch; SEFA 1 construction practice

Specifications

Model series P1 floor-standing
Working widths 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
Overall dimensions 1200/1500/1800 × 850 × 2350mm (full height with base)
Body 5-8mm welded polypropylene (PP)
Liner 5mm PP
Baffle 5mm PP, three-section
Sash 5mm tempered glass, vertical rising, synchronous belt counterweight
Base cabinet Full-height PP, reinforced
Lighting High-brightness LED
Electrical LCD control panel, splash-proof sockets
Exhaust volume 1036 m³/h (1200mm) · 1360.8 m³/h (1500mm) · 1684.8 m³/h (1800mm)
Face velocity 0.4-0.6 m/s at the working opening
Worktop options Ceramic / PP / physical-chemical board
Ductwork options PP duct, PP axial fans — one material from sash to stack
Compliance ASHRAE 110 · SEFA 1 · SEFA 8M

Where you would install it

  • Acid digestion. batch sample preparation with mineral acids at floor scale
  • Perchloric acid work. wash-down-ready PP chain from hood to stack
  • Heavy wet chemistry. large baths, alkali boils and salt-rich processes
  • Plating and surface treatment. electroplating cells and etch lines

Additional information

Width

1200mm, 1500mm, 1800mm

Material

Polypropylene (PP)

Form Factor

Floor-Standing

Sash Type

Vertical Tempered Glass

Airflow Type

CAV, Ducted

Liner Material

Polypropylene (PP)

Worktop Type

Ceramic, Physical-Chemical Board

Compliance

ASHRAE 110, SEFA 1, SEFA 8M

Safety Feature

Low Flow Alarm, Sash Alarm, Spill Containment

Lighting

LED

Application

Acid Digestion, General, Perchloric Acid, Solvent

Reviews

There are no reviews yet.

Be the first to review “PP Floor-Standing Fume Hood”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation
QUESTIONS & ANSWERS

PP Floor-Standing Fume Hood: frequently asked questions

The questions buyers ask most often when specifying PP Floor-Standing Fume Hood, answered by our technical team.

Why PP for perchloric acid?

Perchloric deposits are an organic explosion risk; an all-PP chain — hood, liner, duct, fan — removes the organics where deposits could form, and PP survives the acid itself.

What widths?

1200, 1500 and 1800mm, all welded PP from liner to base cabinet.

What exhaust volume?

1036 / 1360 / 1684 m³/h by width, quoted with PP duct and fan options as one package.

Does it include the worktop?

The worktop is quoted to match the service — ceramic, PP or physical-chemical board.