All-Steel Floor-Standing Fume Hood

SKU FH-AS-F-1200
Unit price · 1200mm · Cold-Rolled Steel · Floor-Standing · Vertical Tempered Glass
Price on request
Final price confirmed by quotationNo online payment required
Width: 1200mm
Material: Cold-Rolled Steel
Form Factor: Floor-Standing
Sash Type: Vertical Tempered Glass
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code WidthMaterialForm FactorSash Type Price Qty Cart action
FH-AS-F-1200 1200mm Cold-Rolled Steel Floor-Standing Vertical Tempered Glass Price on request — Quote
FH-AS-F-1500 1500mm Cold-Rolled Steel Floor-Standing Vertical Tempered Glass Price on request — Quote
FH-AS-F-1800 1800mm Cold-Rolled Steel Floor-Standing Vertical Tempered Glass Price on request — Quote
Total¥0.00

Showing 1 to 3 of 3 entries

Description

Overview

The T1/T3/T5/T6 floor-standing all-steel fume hood carries the chemistry the bench cannot: tall condenser trains, pilot reactors, drum-scale additions. The chamber stands on its own full-height base cabinet with a chemical-resistant worktop, the sash rises to give working access at torso height, and the exhaust runs 1036-1684 m³/h by width.

The body is 1.0mm cold-rolled steel, epoxy powder coated, with a 5mm anti-bet liner and three-section baffle; the sash is 5mm tempered glass on the synchronous counterweight. LED lighting, the LCD control panel and 10A splash-proof sockets come standard, and the VAV variable air volume control is an option for metered facilities.

Floor-standing hoods anchor the heavy end of a ducted installation — where the apparatus is tall, the process is long or the throughput demands a standing workstation. Tell us the tallest assembly and the chemistry, and we will quote the width, the worktop and the exhaust schedule.

Key features

  • Full-height floor-standing body. integral base cabinet with chemical-resistant worktop — tall apparatus and standing workflows
  • 1.0mm cold-rolled steel. epoxy powder coated, knock-down assembly; reinforced base levels on any floor
  • 5mm anti-bet liner and baffle. three-section sweep that holds 0.4-0.6 m/s at every working sash height
  • 5mm tempered glass sash. vertical rising, full-face, counterweighted and cycle-tested
  • LED lighting and LCD panel. 10A splash-proof sockets and vapor-tight chamber lighting
  • Published exhaust volumes. 1036 / 1360 / 1684 m³/h at 1200 / 1500 / 1800mm with matched duct spigots
  • VAV option. variable air volume control for energy-metered facilities

Specifications

Model series T1 / T3 / T5 / T6 floor-standing
Working widths 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft)
Overall dimensions 1200/1500/1800 × 850 × 2350mm (full height with base)
Body 1.0mm cold-rolled steel, epoxy powder coated
Liner 5mm anti-bet board
Baffle 5mm anti-bet board, three-section
Sash 5mm tempered glass, vertical rising, synchronous belt counterweight
Base cabinet Full-height, reinforced, adjustable feet
Lighting High-brightness LED
Electrical LCD control panel, 10A splash-proof sockets
Exhaust volume 1036 m³/h (1200mm) · 1360.8 m³/h (1500mm) · 1684.8 m³/h (1800mm)
Face velocity 0.4-0.6 m/s at the working opening
Worktop options Ceramic / epoxy resin / physical-chemical board
Options VAV control · PP sink · service fixtures · walk-in configurations
Compliance ASHRAE 110 · SEFA 1 · SEFA 8M · ANSI/AIHA Z9.5

Where you would install it

  • Distillation trains. tall condenser and fractionation setups beyond benchtop height
  • Pilot reactors. process development with standing access and full capture
  • Industrial QC. corrosion testing and surface prep at line scale
  • General heavy chemistry. reagent volumes and apparatus that outgrow the bench

Additional information

Width

1200mm, 1500mm, 1800mm

Material

Cold-Rolled Steel

Form Factor

Floor-Standing

Sash Type

Vertical Tempered Glass

Airflow Type

CAV, Ducted, VAV

Liner Material

Anti-Bet Board

Worktop Type

Ceramic, Epoxy Resin, Physical-Chemical Board

Compliance

ANSI/AIHA Z9.5, ASHRAE 110, SEFA 1, SEFA 8M

Safety Feature

Low Flow Alarm, Sash Alarm, Spill Containment

Lighting

LED

Application

Distillation, General, Industrial

Reviews

There are no reviews yet.

Be the first to review “All-Steel Floor-Standing Fume Hood”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation
QUESTIONS & ANSWERS

All-Steel Floor-Standing Fume Hood: frequently asked questions

The questions buyers ask most often when specifying All-Steel Floor-Standing Fume Hood, answered by our technical team.

What is the overall height?

2350mm full height including the integral base cabinet, in all three widths; door and ceiling surveys are confirmed before shipping.

Walk-in configurations?

Yes — where the apparatus is taller than the sash, walk-in hoods enclose it with the chamber floor as the laboratory floor. Quoted from your drawings.

What exhaust volume?

1036 / 1360 / 1684 m³/h by width, with the fan, duct and stack package quoted together.

VAV available?

Yes — the variable air volume option is available across the all-steel floor series.