Laboratory catalog

Class S Autoclaves

Class S autoclaves fill the gap between Class N and Class B, offering programmable, manufacturer-validated cycles tailored to special loads such as single wrapped items, single porous items or other defined load types. Each cycle is validated for the specific load it was designed to sterilize.These programmable autoclaves give laboratories and clinics the flexibility to handle defined special loads without the full vacuum capability of a Class B unit. With cycle storage, digital control and CE-compliant safety interlocks, they deliver consistent, documented sterilization for specific instrument and material requirements.

  • 2Products
  • 0Direct categories
  • Technical support
Laboratory Mall Showcase your products Reach laboratory buyers in one place, all year round. Exhibit with us

Showing all 2 results

  • Biobase BKM-Z Series Class S Autoclave

    Class S (pre-vacuum) -0.1/0.3 MPa

    Price on request

    Contact

    Biobase BKM-Z Series Class S AutoclaveWSH-BIOBASE-BKM-Z-SERIES


    Classification
    Class S (pre-vacuum)
    Design Pressure
    -0.1/0.3 MPa
    Design Temperature
    144°C

    Class S pre-vacuum tabletop autoclave in 24L, 45L and 80L, for wrapped and unwrapped instruments, fabric and culture media, 105-138°C, SUS304 stainless steel chamber.

    View product details
  • Tuttnauer D-Line Class S Autoclave

    Class S (pulsed air removal) 316L electro-polished stainless steel

    Price on request

    Contact

    Tuttnauer D-Line Class S AutoclaveWSH-TUTTNAUER-D-LINE


    Classification
    Class S (pulsed air removal)
    Chamber Material
    316L electro-polished stainless steel
    Door
    Self-locking double safety locking door

    Class S tabletop autoclave in 19.8L and 65L, closed-door active drying with pulsed air removal, 316L electro-polished stainless steel chamber, self-locking door.

    View product details

TECHNICAL DATA

Class S Autoclaves Specifications & Technical Documentation

Select a product to view its specifications, available options and technical documents.

Class S Autoclaves

Tuttnauer D-Line Class S Autoclave

View Product
Classification
Class S (pulsed air removal)
Chamber Material
316L electro-polished stainless steel
Door
Self-locking double safety locking door
Display
Multilingual multi-colour LCD (26 languages)
Form Factor
Tabletop
Control Type
Program Controlled
Heating Method
Electric
Application
Medical
Display Type
LCD
Material
316L Stainless Steel
Door Type
Front Loading
Exhaust Method
Pulsating Vacuum
Chamber Size
19.8L (230×430 mm) · 65L (380×500 mm)
Capacity
19.8L · 65L
Cassette Capacity
2 Full & 2 Half · 8 Full
Power
2200W (230V), 1400W (110V) · 2400W
Voltage
230V / 110V, 50/60 Hz · 230V, 50/60 Hz

APPLICATIONS

Class S Autoclaves Applications & Use Cases

Application-led selection for real laboratory workflows.

Confirm installation needs

Check utilities, ventilation, access and the physical footprint before ordering.

Reduce lifecycle downtime

Evaluate cleaning, preventive maintenance, consumables and service access.

PERFORMANCE & SELECTION

Size the process correctly

Match chamber or platform capacity to typical and peak batches without unnecessary oversizing.

  • Working capacity
  • Load and vessel dimensions
  • Daily throughput
Size the process correctly
CONFIGURATION & COMPATIBILITY

Compare control performance

Review the speed, temperature, uniformity and timer parameters that affect the process.

  • Operating range
  • Stability and uniformity
  • Programs and alarms
Compare control performance
IDENTIFICATION & TRACEABILITY

Clear Product Identification & Specification

Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.

  • Product and model identification
  • Option-specific SKU information
  • Consistent quotation specifications
PRODUCT IDENTIFICATIONClass S Autoclaves
Catalog
Laboratory equipment
Products
2
Selection
Specification-led
QUALITY RECORDS

Traceable Supply & Quality Inspection

Documentation and inspection requirements are confirmed against the selected product and order.

  • Product identification records
  • Pre-delivery checks
  • Documents available on request
Traceable Supply & Quality Inspection
QUALITY STANDARDS

Choose the Right Class S Autoclaves Specification

Compare the specifications that determine application fit and acceptance.

G—01

Capacity & throughput

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—02

Control performance

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—03

Installation

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—04

Maintenance

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
WHY WORK WITH US

Why Choose Our Laboratory Supply Services

Reliable Product Quality

Defined specifications and order-level checks.

Complete Technical Documentation

Documents support selection and compliance.

Flexible Options

Configurations for bench, pilot and production needs.

Professional Technical Support

Guidance on specification and application matching.

Planned Supply Capabilities

Support for recurring and project orders.

Delivery Support

Shipping requirements reviewed for each order.

Contact Our Supply Team
OPTIONS & SPECIFICATIONS

Class S Autoclaves Options & Specifications

Choose the format that suits your application, workload and handling requirements.

Capacity & throughput

Control performance

Installation

Maintenance

TypeCapacity / OptionMaterial / SpecificationSuitable ApplicationStorage / Handling
Capacity & throughputBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
Control performanceBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
InstallationBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
MaintenanceBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
INSTALLATION, HANDLING & MAINTENANCE

Class S Autoclaves Handling & Care Guide

Follow the product manual and site procedures for safe installation, use and maintenance.

  1. 01

    Check Product & Accessories

    Confirm model, options and supplied components.

  2. 02

    Review Product Documentation

    Read installation and safety instructions before use.

  3. 03

    Prepare the Working Environment

    Confirm space, utilities and operating conditions.

  4. 04

    Plan Routine Care

    Follow cleaning, inspection and maintenance guidance.

Class S Autoclaves Handling & Care Guide
VIDEOS

Manufacturing & Quality Process

Category video library

Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.

TECHNICAL RESOURCES

Related Articles & Technical Resources

October 29, 2026

What to Include in a Laboratory Product Quote

Read More
October 29, 2026

A Practical Guide to Laboratory Glassware

Read More
October 29, 2026

How to Choose a Benchtop Centrifuge

Read More
GET A QUOTATION

Request a Class S Autoclaves Quotation

Tell us your required products, specifications and quantities. Our sales team will contact you with suitable supply options.