WSHLab A2 Advanced Biosafety Cabinet

SKU BSC-A2A-412-115-NSF
Unit price · 4 ft / 1.2 m · 12 in / 305 mm · 115V · NSF-ANSI-49 · Small Animal Cage Changing · Dual Airflow Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 12 in / 305 mm
Electrical: 115V
Performance Standard: NSF-ANSI-49
Application: Small Animal Cage Changing
Control System: Dual Airflow Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-A2A-412-115-NSF WSHLab A2 Advanced Biosafety Cabinet Each 4 ft / 1.2 m 12 in / 305 mm 115V NSF-ANSI-49 Small Animal Cage Changing Dual Airflow Sensor Price on request — Quote
BSC-A2A-512-230-CE WSHLab A2 Advanced Biosafety Cabinet Each 5 ft / 1.5 m 12 in / 305 mm 230V CE Small Animal Cage Changing Dual Airflow Sensor Price on request — Quote
BSC-A2A-614-230-EN WSHLab A2 Advanced Biosafety Cabinet Each 6 ft / 1.8 m 14 in / 356 mm 230V EN-12469 Small Animal Cage Changing Dual Airflow Sensor Price on request — Quote
Total¥0.00

Showing 1 to 3 of 3 entries

Description

Overview

Changing cages in a standard 8 in cabinet is awkward by design: the cage does not fit through the opening, so operators tilt it, break the air curtain and lose containment. The A2 Advanced opens to 12 in or 14 in, which is enough to pass a standard rodent cage through upright.

The second difference is the airflow monitoring. Cage changing generates a burst of bedding dust and ammonia at the moment the cage is opened, and the filter loads unevenly. Two sensors — downflow and inflow — let the cabinet alarm on the side that actually drifted, instead of a single combined reading that tells you something is wrong but not what.

It is specified by vivariums, contract research organisations and academic animal facilities, usually alongside a smaller A2 Standard for sample work.

Key features

  • 12 in and 14 in sash openings. Standard rodent cages pass through upright, so the operator does not tilt the cage into the air curtain.
  • Dual airflow sensors. Downflow and inflow are monitored separately. A loaded supply filter and a disturbed inflow alarm differently, which is what you need to know during cage changing.
  • Bedding-tolerant pre-filter. A coarse pre-filter ahead of the supply ULPA filter catches bedding dust, extending the interval between filter changes in a dusty room.
  • Coved stainless work zone with drain. Liquid waste and bedding debris collect in a radiused sump that wipes out in one pass.

Specifications

Airflow class Class II Type A2 — 30% exhausted, 70% recirculated
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s at the tested sash height
Sash opening 12 in / 305 mm standard; 14 in / 356 mm on the 6 ft model
Filter ULPA U15, 99.9995% at 0.12 µm, supply and exhaust
Working widths 4 ft / 1.2 m, 5 ft / 1.5 m, 6 ft / 1.8 m
External dimensions 1300-1800 × 800 × 2250 mm (W × D × H)
Internal dimensions 1150-1625 × 600 × 660 mm (W × D × H)
Power 1800 VA maximum, 230V or 115V single phase
Noise ≤65 dB(A)
Illumination ≥1000 lx at the work surface
Certification NSF/ANSI 49, CE, UKCA, EN 12469

Where you would install it

  • Vivarium cage changing. Rodent cages pass through a 12-14 in opening without tilting into the air curtain.
  • SPF and barrier facilities. Containment of bedding dust and allergens at the point of cage opening.
  • Contract research. High-throughput cage change stations where filter loading is continuous.

Frequently asked questions

Will a 12 in opening hold containment?

Yes, at the tested sash height the inflow is still 0.53 m/s and the cabinet is certified at that opening. The alarm monitors the opening, so working above it is flagged.

Can the cabinet be used for cell culture too?

Yes. The A2 Advanced is still a Type A2 cabinet; the larger opening simply makes it less comfortable for seated bench work.

Additional information

Width

4 ft / 1.2 m, 5 ft / 1.5 m, 6 ft / 1.8 m

Work Access Opening

12 in / 305 mm, 14 in / 356 mm

Electrical

115V, 230V

Performance Standard

NSF-ANSI-49, CE, UKCA, EN-12469, UL

Application

Small Animal Cage Changing

Control System

Dual Airflow Sensor

Reviews

There are no reviews yet.

Be the first to review “WSHLab A2 Advanced Biosafety Cabinet”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation