Laboratory catalog

Benchtop & Compact Climate Chambers

The bench-top category is where specifications are most often stretched. A 36 litre cabinet can reach 60 °C, but its humidity floor is usually 30 %RH, which rules out the 25 %RH condition for semi-permeable containers. This family covers the 36 to 250 litre chambers, and states the humidity floor for each size, because that is the number that decides whether the chamber is usable.

  • 2Products
  • 0Direct categories
  • Technical support
Benchtop & Compact Climate Chambers Laboratory equipment

Showing all 2 results

  • Benchtop & Compact Climate Chambers

    Mini Climate Chamber

    SKU: CC-MINI-CLIMATE-CHAMBER-GROUP

    Brand / manufacturer
    Chinese OEM benchtop builders
    Platform
    Mini bench-top climate cabinet, 36 to 125 L
    Temperature Range
    0 to +60 °C on the 36 L build; -10 to +85 °C available on request
    Humidity Range
    30 to 95 %RH standard; 20 to 98 %RH on request
    Price on request
  • Benchtop & Compact Climate Chambers

    Tabletop Climate Chamber

    SKU: CC-TABLETOP-CLIMATE-CHAMBER-GROUP

    Brand / manufacturer
    Chinese OEM benchtop builders
    Platform
    Bench-top constant temperature and humidity cabinet, 22 to 200 L
    Temperature Range
    -40 to +150 °C depending on option; -20 to +100 °C on the standard build
    Humidity Range
    20 to 98 %RH standard; 10 to 98 %RH on request
    Reference CN¥12,800–20,000 / per unitCNY reference · Final price by quotation

TECHNICAL DATA

Benchtop & Compact Climate Chambers Specifications & Technical Documentation

Select a product to view its specifications, available options and technical documents.

Benchtop & Compact Climate Chambers

Tabletop Climate Chamber

View Product
Brand / manufacturer
Chinese OEM benchtop builders
Platform
Bench-top constant temperature and humidity cabinet, 22 to 200 L
Temperature Range
-40 to +150 °C depending on option; -20 to +100 °C on the standard build
Humidity Range
20 to 98 %RH standard; 10 to 98 %RH on request
Temperature Fluctuation
≤±0.5 °C; uniformity ≤2 °C; deviation ±2 °C
Humidity Fluctuation
≤±2 %RH; deviation ±3 %RH
Ramp Rate
3 °C/min heating, 1 °C/min cooling unloaded
Control
7-inch touchscreen with 100 programs and 10,000 segments, 9-group PID autotuning, RS232/USB/RJ45 export
Construction
1.0 mm SUS304 interior, powder-coated cold-rolled steel exterior, 80 mm insulation, Ø50 mm cable port
Refrigeration
Tecumseh hermetic compressor with R404A/R23 cascade on low-temperature builds
Documentation
Bench-top units are built to order and the listings below are Chinese marketplace reference prices, not brand list prices.
Series
HYH / DR-H series
Configuration
65 L benchtop · 65 L · 130 L benchtop · 130 L

APPLICATIONS

Benchtop & Compact Climate Chambers Applications & Use Cases

Application-led selection for real laboratory workflows.

When to step up to a floor-standing unit

The crossover is about 250 L, and it is driven by humidity floor and shelf area rather than by volume.

What to check on a bench-top quotation

At this price point the accessories decide the usefulness of the chamber.

PERFORMANCE & SELECTION

The humidity floor is the real limit

Small chambers humidify easily and dehumidify badly, and that asymmetry defines what they can test.

  • 30 %RH is the typical floor for a 36 L bench-top cabinet, because dehumidification relies on cooling.
  • 20 %RH needs active drying, which usually means a larger cabinet with a desiccant or dry-air path.
  • 10 %RH is a floor-standing chamber requirement and rarely appears below 250 L.
  • If the protocol is 25 °C / 60 %RH, a bench-top unit is fine
  • if it is 30 °C / 35 %RH, it is not.
The humidity floor is the real limit
CONFIGURATION & COMPATIBILITY

Footprint, stacking and heat

On a bench, the constraint is often the air around the chamber rather than the chamber itself.

  • A 65 L unit fits a 1,200 mm bench
  • a 130 L unit usually needs its own low cabinet.
  • Stacking frames let two 130 L units share a footprint, but the lower unit then rejects heat into the upper.
  • Bench-top compressors reject 500 to 1,500 W into the room, which matters in a small laboratory.
  • Noise is 55 to 65 dB(A)
  • check it if the chamber sits next to a desk.
Footprint, stacking and heat
IDENTIFICATION & TRACEABILITY

Clear Product Identification & Specification

Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.

  • Product and model identification
  • Option-specific SKU information
  • Consistent quotation specifications
PRODUCT IDENTIFICATIONBenchtop & Compact Climate Chambers
Catalog
Laboratory equipment
Products
2
Selection
Specification-led
QUALITY RECORDS

Traceable Supply & Quality Inspection

Documentation and inspection requirements are confirmed against the selected product and order.

  • Product identification records
  • Pre-delivery checks
  • Documents available on request
Traceable Supply & Quality Inspection
QUALITY STANDARDS

Choose the Right Benchtop & Compact Climate Chambers Specification

Compare the specifications that determine application fit and acceptance.

G—01

humidity floor by size

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—02

bench footprint

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—03

stackability

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—04

temperature range

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—05

noise and heat rejection

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
WHY WORK WITH US

Why Choose Our Laboratory Supply Services

Reliable Product Quality

Defined specifications and order-level checks.

Complete Technical Documentation

Documents support selection and compliance.

Flexible Options

Configurations for bench, pilot and production needs.

Professional Technical Support

Guidance on specification and application matching.

Planned Supply Capabilities

Support for recurring and project orders.

Delivery Support

Shipping requirements reviewed for each order.

Contact Our Supply Team
OPTIONS & SPECIFICATIONS

Benchtop & Compact Climate Chambers Options & Specifications

Choose the format that suits your application, workload and handling requirements.

humidity floor by size

bench footprint

stackability

temperature range

noise and heat rejection

TypeCapacity / OptionMaterial / SpecificationSuitable ApplicationStorage / Handling
humidity floor by sizeBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
bench footprintBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
stackabilityBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
temperature rangeBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
noise and heat rejectionBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
INSTALLATION, HANDLING & MAINTENANCE

Benchtop & Compact Climate Chambers Handling & Care Guide

Follow the product manual and site procedures for safe installation, use and maintenance.

  1. 01

    Check Product & Accessories

    Confirm model, options and supplied components.

  2. 02

    Review Product Documentation

    Read installation and safety instructions before use.

  3. 03

    Prepare the Working Environment

    Confirm space, utilities and operating conditions.

  4. 04

    Plan Routine Care

    Follow cleaning, inspection and maintenance guidance.

Benchtop & Compact Climate Chambers Handling & Care Guide
VIDEOS

Manufacturing & Quality Process

Category video library

Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.

TECHNICAL RESOURCES

Related Articles & Technical Resources

October 29, 2026

What to Include in a Laboratory Product Quote

Read More
October 29, 2026

A Practical Guide to Laboratory Glassware

Read More
October 29, 2026

How to Choose a Benchtop Centrifuge

Read More
GET A QUOTATION

Request a Benchtop & Compact Climate Chambers Quotation

Tell us your required products, specifications and quantities. Our sales team will contact you with suitable supply options.