WSHLab A2 Floor-Standing Biosafety Cabinet

SKU BSC-A2F-208-230-EN
Unit price · 2 ft / 0.6 m · 8 in / 203 mm · 230V · EN-12469 · Tissue Culture · Single Airflow Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 2 ft / 0.6 m
Work Access Opening: 8 in / 203 mm
Electrical: 230V
Performance Standard: EN-12469
Application: Tissue Culture
Control System: Single Airflow Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-A2F-208-230-EN WSHLab A2 Floor-Standing Biosafety Cabinet Each 2 ft / 0.6 m 8 in / 203 mm 230V EN-12469 Tissue Culture Single Airflow Sensor Price on request — Quote
BSC-A2F-308-230-EN WSHLab A2 Floor-Standing Biosafety Cabinet Each 3 ft / 0.9 m 8 in / 203 mm 230V EN-12469 Tissue Culture Single Airflow Sensor Price on request — Quote
BSC-A2F-410-230-EN WSHLab A2 Floor-Standing Biosafety Cabinet Each 4 ft / 1.2 m 10 in / 254 mm 230V EN-12469 Tissue Culture Pressure Sensor Price on request — Quote
BSC-A2F-610-230-EN WSHLab A2 Floor-Standing Biosafety Cabinet Each 6 ft / 1.8 m 10 in / 254 mm 230V EN-12469 Tissue Culture Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 4 of 4 entries

Description

Overview

A floor-standing cabinet puts the work surface at 750 mm and the cabinet on its own frame, which is what you want when the cabinet is part of a cleanroom fit-out rather than an addition to a bench. There is room underneath for a vacuum pump, and the service access is at the front rather than the side.

The range runs from 2 ft to 6 ft, with a manual sash on the standard models and a motorised sash on the HA configuration. All versions are tested to EN 12469 and carry CE marking; the NA configuration is built for NSF/ANSI 49 markets.

It is the cabinet we supply into pharmaceutical cleanrooms and high-use academic laboratories, where the cabinet is specified from the room drawing rather than from a catalogue page.

Key features

  • 750 mm work surface. Seated or standing operation without a separate bench, which is how most cleanroom suites are planned.
  • Manual or motorised sash. Standard models use a counterbalanced manual sash; the HA configuration adds a motorised sash with anti-pinch.
  • EN 12469 and NSF 49 configurations. The same cabinet is available with either certification, so a European tender and a US protocol can be served from one platform.
  • Front service access. Filters and blower are reached from the front, so the cabinet does not have to be pulled out of a cleanroom wall.

Specifications

Airflow class Class II Type A2 — 30% exhausted, 70% recirculated
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Sash operation Manual (GL) or motorised (HA)
Work surface height 750 mm
Filter ULPA U15, 99.9995% at 0.12 µm
Working widths 2 ft / 0.6 m to 6 ft / 1.8 m
External dimensions 700-1800 × 800 × 2200-2260 mm (W × D × H)
Internal dimensions 600-1625 × 600 × 650 mm (W × D × H)
Exhaust volume 230-520 m³/h depending on width
Power 1100 VA plus 500 W socket load
Noise ≤65 dB(A)
Certification EN 12469 (TÜV), CE, NSF/ANSI 49 configuration

Where you would install it

  • Pharmaceutical cleanrooms. Floor-standing cabinets planned into the room rather than added to a bench.
  • High-use academic laboratories. A cabinet that can take a pump underneath and be serviced from the front.
  • Public tenders. EN 12469 certification with CE marking for European procurement.

Frequently asked questions

What is the difference between GL, NA and HA?

GL is the CE/EN 12469 configuration with a manual sash, NA is the NSF/ANSI 49 configuration for North America, and HA adds a motorised sash.

Does it need to be fixed to the floor?

It stands on levelling feet and castors and does not need floor fixing, though we recommend a seismic restraint in seismically active regions.

Additional information

Width

2 ft / 0.6 m, 3 ft / 0.9 m, 4 ft / 1.2 m, 6 ft / 1.8 m

Work Access Opening

8 in / 203 mm, 10 in / 254 mm

Electrical

230V

Performance Standard

CE, EN-12469

Application

Tissue Culture

Control System

Single Airflow Sensor, Pressure Sensor