WSHLab A2 Premium Biosafety Cabinet

SKU BSC-A2P-410-230-EN
Unit price · 4 ft / 1.2 m · 10 in / 254 mm · 230V · EN-12469 · Drug Compounding · Pressure Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 10 in / 254 mm
Electrical: 230V
Performance Standard: EN-12469
Application: Drug Compounding
Control System: Pressure Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-A2P-410-230-EN WSHLab A2 Premium Biosafety Cabinet Each 4 ft / 1.2 m 10 in / 254 mm 230V EN-12469 Drug Compounding Pressure Sensor Price on request — Quote
BSC-A2P-510-230-CE WSHLab A2 Premium Biosafety Cabinet Each 5 ft / 1.5 m 10 in / 254 mm 230V CE Drug Compounding Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 2 of 2 entries

Description

Overview

In a compounding pharmacy the cabinet is not judged on how quietly it runs, but on whether you can prove it was running correctly when the batch was prepared. The A2 Premium replaces the airflow sensor with a pressure sensor and a controller that logs the state of the cabinet, so the daily check has something to attach to.

The cabinet is built to EN 12469 with a pressure-decay-style plenum, a digital display showing downflow, inflow and filter load, and dry contacts for a building management system. The sash is motorised, which matters when the operator is holding a syringe and cannot reach for a handle.

It is specified for USP 797 sterile compounding of non-hazardous drugs. If your formulary includes hazardous drugs under USP 800, use the B2 Total Exhaust instead — no A2 cabinet, however well monitored, is acceptable there.

Key features

  • Pressure-based airflow control. The controller regulates plenum pressure rather than fan speed, which keeps the airflow stable as the filters load and the room pressure changes.
  • Traceable operating record. Downflow, inflow, filter load and alarm history are held in the controller and can be exported for the batch file.
  • Motorised sash with anti-pinch. The sash is driven, not lifted. Operators working with both hands keep their posture and the sash stops on obstruction.
  • Dry contacts for BMS. Alarm and status outputs are available as volt-free contacts, so the cabinet can report into the pharmacy monitoring system.

Specifications

Airflow class Class II Type A2 — 30% exhausted, 70% recirculated
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Control Pressure sensor, digital display, alarm history, BMS dry contacts
Sash Motorised, tempered glass, anti-pinch, height alarm
Filter ULPA U15, 99.9995% at 0.12 µm, supply and exhaust
Working widths 4 ft / 1.2 m, 5 ft / 1.5 m
External dimensions 1300-1500 × 800 × 2250 mm (W × D × H)
Internal dimensions 1150-1350 × 600 × 660 mm (W × D × H)
Power 1800 VA maximum, 230V single phase
Noise ≤65 dB(A)
Illumination ≥1000 lx at the work surface
Certification EN 12469, CE, UKCA, DIN 12980 configuration available

Where you would install it

  • USP 797 compounding. Sterile non-hazardous compounding with a documented airflow record.
  • Hospital pharmacy. IV admixture preparation where the cabinet reports into the cleanroom BMS.
  • Compounding outsourcing. Batch records that need cabinet status at the time of preparation.

Frequently asked questions

Is this cabinet suitable for hazardous drugs?

No. Hazardous drug compounding under USP 800 requires total exhaust. Specify the B2 Total Exhaust.

What does the controller actually log?

Downflow and inflow setpoints and actual values, filter load, sash position and every alarm event, with timestamps that can be exported for the batch record.

Additional information

Width

4 ft / 1.2 m, 5 ft / 1.5 m

Work Access Opening

10 in / 254 mm

Electrical

230V

Performance Standard

CE, UKCA, EN-12469, DIN-12980

Application

Drug Compounding

Control System

Pressure Sensor

Reviews

There are no reviews yet.

Be the first to review “WSHLab A2 Premium Biosafety Cabinet”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation