WSHLab B2 Floor-Standing Biosafety Cabinet

SKU BSC-B2F-408-230-EN
Unit price · 4 ft / 1.2 m · 8 in / 203 mm · 230V · EN-12469 · Cytotoxic API Powders · Pressure Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 8 in / 203 mm
Electrical: 230V
Performance Standard: EN-12469
Application: Cytotoxic API Powders
Control System: Pressure Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-B2F-408-230-EN WSHLab B2 Floor-Standing Biosafety Cabinet Each 4 ft / 1.2 m 8 in / 203 mm 230V EN-12469 Cytotoxic API Powders Pressure Sensor Price on request — Quote
BSC-B2F-408-115-NSF WSHLab B2 Floor-Standing Biosafety Cabinet Each 4 ft / 1.2 m 8 in / 203 mm 115V NSF-ANSI-49 Cytotoxic API Powders Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 2 of 2 entries

Description

Overview

The floor-standing B2 is the version specified from a room drawing: the work surface is at 750 mm, the frame carries the cabinet, and the duct rises directly from the exhaust collar rather than being routed around a bench.

It is available in the GL configuration for EN 12469 markets and the NA configuration for NSF/ANSI 49, with the same exhaust volume so the duct design does not change with the certification.

Most units go into hospital pharmacies and cytotoxic suites where the cabinet is part of a fit-out rather than an equipment purchase.

Key features

  • 750 mm work surface. Seated compounding height without a separate bench, which keeps the duct run short.
  • EN 12469 or NSF 49 from one frame. The certification changes the paperwork, not the duct or footprint.
  • Front service access. Filter and blower service from the front, so the cabinet does not have to come out of the room.
  • Spill sump. A radiused stainless sump holds a spill until it can be cleaned, without reaching a seam.

Specifications

Airflow class Class II Type B2 — 100% exhaust, no recirculation
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Exhaust volume 1400 m³/h
Work surface height 750 mm
Filter ULPA U15, 99.9995% at 0.12 µm
Working width 4 ft / 1.2 m
External dimensions 1087 × 800 × 2260 mm (W × D × H)
Internal dimensions 980 × 600 × 650 mm (W × D × H)
Power 1100 VA plus 500 W socket load
Noise ≤65 dB(A)
Certification EN 12469 (TÜV), CE, NSF/ANSI 49 configuration

Where you would install it

  • Hospital pharmacy fit-out. A cabinet planned into a negative-pressure compounding room.
  • Cytotoxic suites. Total exhaust with a 750 mm work surface for seated preparation.
  • Public tender supply. EN 12469 certification with CE marking for European procurement.

Frequently asked questions

How is this different from the B2 Total Exhaust?

Same airflow class; the floor-standing version moves the work surface to 750 mm and removes the bench, which suits a cleanroom fit-out.

Does the duct have to go straight up?

It can run horizontally at high level, but every bend adds static pressure. Keep the run short and size the fan for the worst case.

Additional information

Width

4 ft / 1.2 m

Work Access Opening

8 in / 203 mm

Electrical

115V, 230V

Performance Standard

NSF-ANSI-49, CE, EN-12469, UL

Application

Cytotoxic API Powders

Control System

Pressure Sensor

Reviews

There are no reviews yet.

Be the first to review “WSHLab B2 Floor-Standing Biosafety Cabinet”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation