Description
Overview
The T1/T3/T5/T6 floor-standing all-steel fume hood carries the chemistry the bench cannot: tall condenser trains, pilot reactors, drum-scale additions. The chamber stands on its own full-height base cabinet with a chemical-resistant worktop, the sash rises to give working access at torso height, and the exhaust runs 1036-1684 m³/h by width.
The body is 1.0mm cold-rolled steel, epoxy powder coated, with a 5mm anti-bet liner and three-section baffle; the sash is 5mm tempered glass on the synchronous counterweight. LED lighting, the LCD control panel and 10A splash-proof sockets come standard, and the VAV variable air volume control is an option for metered facilities.
Floor-standing hoods anchor the heavy end of a ducted installation — where the apparatus is tall, the process is long or the throughput demands a standing workstation. Tell us the tallest assembly and the chemistry, and we will quote the width, the worktop and the exhaust schedule.
Key features
- Full-height floor-standing body. integral base cabinet with chemical-resistant worktop — tall apparatus and standing workflows
- 1.0mm cold-rolled steel. epoxy powder coated, knock-down assembly; reinforced base levels on any floor
- 5mm anti-bet liner and baffle. three-section sweep that holds 0.4-0.6 m/s at every working sash height
- 5mm tempered glass sash. vertical rising, full-face, counterweighted and cycle-tested
- LED lighting and LCD panel. 10A splash-proof sockets and vapor-tight chamber lighting
- Published exhaust volumes. 1036 / 1360 / 1684 m³/h at 1200 / 1500 / 1800mm with matched duct spigots
- VAV option. variable air volume control for energy-metered facilities
Specifications
| Model series | T1 / T3 / T5 / T6 floor-standing |
|---|---|
| Working widths | 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft) |
| Overall dimensions | 1200/1500/1800 × 850 × 2350mm (full height with base) |
| Body | 1.0mm cold-rolled steel, epoxy powder coated |
| Liner | 5mm anti-bet board |
| Baffle | 5mm anti-bet board, three-section |
| Sash | 5mm tempered glass, vertical rising, synchronous belt counterweight |
| Base cabinet | Full-height, reinforced, adjustable feet |
| Lighting | High-brightness LED |
| Electrical | LCD control panel, 10A splash-proof sockets |
| Exhaust volume | 1036 m³/h (1200mm) · 1360.8 m³/h (1500mm) · 1684.8 m³/h (1800mm) |
| Face velocity | 0.4-0.6 m/s at the working opening |
| Worktop options | Ceramic / epoxy resin / physical-chemical board |
| Options | VAV control · PP sink · service fixtures · walk-in configurations |
| Compliance | ASHRAE 110 · SEFA 1 · SEFA 8M · ANSI/AIHA Z9.5 |
Where you would install it
- Distillation trains. tall condenser and fractionation setups beyond benchtop height
- Pilot reactors. process development with standing access and full capture
- Industrial QC. corrosion testing and surface prep at line scale