WSHLab B2 Total Exhaust Biosafety Cabinet

SKU BSC-B2-408-115-NSF
Unit price · 4 ft / 1.2 m · 8 in / 203 mm · 115V · NSF-ANSI-49 · Cytotoxic API Powders · Pressure Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 8 in / 203 mm
Electrical: 115V
Performance Standard: NSF-ANSI-49
Application: Cytotoxic API Powders
Control System: Pressure Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-B2-408-115-NSF WSHLab B2 Total Exhaust Biosafety Cabinet Each 4 ft / 1.2 m 8 in / 203 mm 115V NSF-ANSI-49 Cytotoxic API Powders Pressure Sensor Price on request — Quote
BSC-B2-610-230-CE WSHLab B2 Total Exhaust Biosafety Cabinet Each 6 ft / 1.8 m 10 in / 254 mm 230V CE Drug Compounding Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 2 of 2 entries

Description

Overview

Every design decision in the B2 follows from one requirement: no air returns from the work zone to the room. The exhaust filter, the plenum, the bag-out port and the duct are all part of the containment boundary, and the cabinet is certified as a system rather than as a box.

That makes the installation a project. You need a dedicated duct sized to the exhaust volume, make-up air to match it, and a room that stays negative to the corridor at full flow. A B2 cabinet on an undersized duct will alarm continuously and will not hold containment, however good the cabinet is.

WSHLab builds the B2 from 4 ft to 6 ft, with a pressure sensor that holds total exhaust as the filters load, and a bag-out arrangement for the exhaust filter so service does not open the contaminated plenum to the room.

Key features

  • 100% total exhaust. No recirculation path exists. Everything that enters the work zone leaves through the exhaust ULPA filter and the duct.
  • Bag-out filter access. The exhaust filter is changed through a bag-out port on the contaminated side, protecting the service engineer and the room.
  • Pressure sensor and duct static alarm. The cabinet monitors plenum pressure and duct static separately, so a blocked duct alarms before containment is lost.
  • Cytotoxic-rated configuration. UL 1805 and UL 586 configurations, stainless work zone and a coved sump for spill control.

Specifications

Airflow class Class II Type B2 — 100% exhaust, no recirculation
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Exhaust volume 1200 m³/h (4 ft) to 1900 m³/h (6 ft)
Duct connection Hard duct, sized to the exhaust volume
Filter ULPA U15, 99.9995% at 0.12 µm, supply and exhaust
Working widths 4 ft / 1.2 m, 6 ft / 1.8 m
External dimensions 1100-1800 × 775 × 2250 mm (W × D × H)
Internal dimensions 940-1625 × 600 × 660 mm (W × D × H)
Power 1800 VA maximum, 230V or 115V single phase
Noise ≤65 dB(A)
Certification NSF/ANSI 49, UL 1805, UL 586, CE, UKCA, EN 12469

Where you would install it

  • USP 800 compounding. Hazardous drug preparation with total external exhaust.
  • Cytotoxic API handling. Powder weighing and dispensing where particles must not return to the room.
  • Volatile toxic chemicals. Solvent and reagent work that cannot be recirculated.

Frequently asked questions

Can a canopy connection make an A2 cabinet equivalent to B2?

A canopy captures the exhaust but the cabinet still recirculates internally, so it is not equivalent. For USP 800, specify B2.

What duct size do I need?

Size for the exhaust volume on the datasheet — 1200 m³/h for the 4 ft model, 1900 m³/h for the 6 ft — and keep duct velocity within the range your HVAC engineer specifies.

Additional information

Width

4 ft / 1.2 m, 6 ft / 1.8 m

Work Access Opening

8 in / 203 mm, 10 in / 254 mm

Electrical

115V, 230V

Performance Standard

NSF-ANSI-49, CE, UKCA, EN-12469, UL, UL-1805, UL-586

Application

Drug Compounding, Cytotoxic API Powders

Control System

Pressure Sensor