WSHLab B1 Hybrid Exhaust Biosafety Cabinet

SKU BSC-B1-408-230-CE
Unit price · 4 ft / 1.2 m · 8 in / 203 mm · 230V · CE · Volatile Chemical Work · Pressure Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 8 in / 203 mm
Electrical: 230V
Performance Standard: CE
Application: Volatile Chemical Work
Control System: Pressure Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-B1-408-230-CE WSHLab B1 Hybrid Exhaust Biosafety Cabinet Each 4 ft / 1.2 m 8 in / 203 mm 230V CE Volatile Chemical Work Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 1 of 1 entries

Description

Overview

B1 is specified by laboratories that cannot justify two cabinets: the work is biological, but the protocol occasionally involves a volatile toxic chemical, and an A2 cabinet would recirculate it back over the work surface.

The cabinet sends about seventy per cent of its air to a dedicated duct and recirculates the rest. A pressure sensor holds that split as the filters load. The remaining recirculation is why B1 is limited to small volumes — it is a mixed-exhaust compromise, not a total-exhaust solution.

If the chemistry is incidental, B1 works and costs less to install than B2. If the chemistry is the point, specify B2.

Key features

  • 70/30 split held by pressure control. The exhaust fraction does not drift as the supply and exhaust filters load at different rates.
  • Smaller duct than B2. About a third less exhaust volume than a total-exhaust cabinet of the same width, which reduces make-up air and duct size.
  • Pressure sensor with alarms. Duct static, downflow and inflow are monitored; the alarm tells you which side moved.
  • ULPA on both paths. Supply and exhaust filters are U15, so the recirculated fraction is as clean as the supply air.

Specifications

Airflow class Class II Type B1 — about 70% ducted exhaust, 30% recirculated
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Exhaust connection Dedicated duct, 4 in / 100 mm collar
Filter ULPA U15, 99.9995% at 0.12 µm, supply and exhaust
Working width 4 ft / 1.2 m
External dimensions 1300 × 800 × 2250 mm (W × D × H)
Internal dimensions 1150 × 600 × 660 mm (W × D × H)
Power 1800 VA maximum, 230V single phase
Noise ≤65 dB(A)
Certification CE, UKCA, EN 12469

Where you would install it

  • Radiolabelling and tracers. Small-volume volatile work inside a biological protocol.
  • Method development. Solvent handling that does not justify a second, dedicated cabinet.
  • Process development. Pilot work where the chemistry is incidental to the biology.

Frequently asked questions

How much chemical can I evaporate in a B1?

Treat it as small-volume work. The recirculated 30% carries a fraction of the vapour back over the work surface, so the exhausted volume — not the cabinet size — sets the limit.

Can the duct be shared with a fume hood?

No. A shared manifold makes the exhaust split unstable and the cabinet will alarm. Run a dedicated duct.

Additional information

Width

4 ft / 1.2 m

Work Access Opening

8 in / 203 mm

Electrical

230V

Performance Standard

CE, UKCA, EN-12469

Application

Volatile Chemical Work

Control System

Pressure Sensor