WSHLab C1 Convertible Biosafety Cabinet

SKU BSC-C1-408-230-CE
Unit price · 4 ft / 1.2 m · 8 in / 203 mm · 230V · CE · Multi-purpose · Pressure Sensor
Price on request
Final price confirmed by quotationNo online payment required
Width: 4 ft / 1.2 m
Work Access Opening: 8 in / 203 mm
Electrical: 230V
Performance Standard: CE
Application: Multi-purpose
Control System: Pressure Sensor
Total Price on request

Need bulk quantities or contract supply?Request a quotation with your required specifications.
Secure cart and checkout Verified listed-price options B2B quotation support Dispatch confirmed with your order

Compare every available specification below, or use the option selector above for a quicker purchase.

Cat Code Description Quantity WidthWork Access OpeningElectricalPerformance StandardApplicationControl System Price Qty Cart action
BSC-C1-408-230-CE WSHLab C1 Convertible Biosafety Cabinet Each 4 ft / 1.2 m 8 in / 203 mm 230V CE Multi-purpose Pressure Sensor Price on request — Quote
Total¥0.00

Showing 1 to 1 of 1 entries

Description

Overview

The C1 is for the laboratory that cannot answer the airflow question once and for all. One month the work is cell culture; the next it is sample preparation with solvents, and the safety officer asks why the cabinet recirculates.

A damper and a mode interlock switch the cabinet between A2 behaviour (30% exhaust) and B2 behaviour (100% exhaust). The duct is installed once and sized for B2, so the building work happens at commissioning rather than at the next protocol change.

It costs more than an A2 and less than an A2 plus a B2, and it needs a written SOP for the mode change. For core facilities and contract research organisations, that is usually a good trade.

Key features

  • A2 and B2 modes. Recirculating mode for biology, total exhaust for chemistry, on the same work zone.
  • Mode interlock. The cabinet will not run a total-exhaust protocol in recirculating mode, and the sash is locked during a mode change.
  • Duct sized once. The duct and make-up air are sized for B2 so the building does not need rework when protocols change.
  • Pressure sensor. Plenum pressure and duct static are monitored in both modes, with a single alarm set.

Specifications

Airflow class Class II Type C1 — convertible A2 / B2
Modes A2: 30% exhaust, 70% recirculation; B2: 100% exhaust
Downflow velocity 0.33 ± 0.025 m/s
Inflow velocity 0.53 ± 0.025 m/s
Exhaust volume 1400 m³/h in B2 mode
Filter ULPA U15, 99.9995% at 0.12 µm
Working width 4 ft / 1.2 m
External dimensions 1300 × 800 × 2250 mm (W × D × H)
Internal dimensions 1150 × 600 × 660 mm (W × D × H)
Power 1800 VA maximum, 230V
Noise ≤65 dB(A)
Certification CE, UKCA, EN 12469, certified in both modes

Where you would install it

  • Core facilities. Mixed users with different airflow requirements on the same cabinet.
  • Contract research. Protocols that rotate between biology and chemistry.
  • Teaching. One cabinet that can demonstrate both airflow classes.

Frequently asked questions

Is the cabinet certified in both modes?

Yes. Field certification covers both A2 and B2 operation, and the mode must be recorded in the certification report.

What happens if someone changes mode mid-protocol?

The interlock requires the cabinet to be empty and the sash closed. The mode change is a logged procedure, not a switch you can flip during work.

Additional information

Width

4 ft / 1.2 m

Work Access Opening

8 in / 203 mm

Electrical

230V

Performance Standard

CE, UKCA, EN-12469

Application

Multi-purpose

Control System

Pressure Sensor

Reviews

There are no reviews yet.

Be the first to review “WSHLab C1 Convertible Biosafety Cabinet”

Your email address will not be published. Required fields are marked *

Technical documents

Datasheets, certificates and safety documents are available from our product specialists.

Request documentation