Description
Overview
The T1/T5/T6 benchtop all-steel fume hood is the general purpose workhorse of the WSHLAB ducted range: a 1.0mm cold-rolled steel body with epoxy powder coating, a 5mm anti-bet board liner and baffle, and a 5mm tempered glass vertical sash on a synchronous belt counterweight. It mounts on a standard bench or a matching base cabinet and ducts from the top plenum.
The aerodynamics are the same platform as every WSHLAB hood: an airfoil sill, a three-section baffle sweeping floor, work zone and ceiling, and a balanced exhaust plenum that holds 0.4-0.6 m/s of face velocity across the opening at any working sash height. Exhaust volumes run 1036 m³/h at 1200mm, 1360 m³/h at 1500mm and 1684 m³/h at 1800mm — published so your fan and duct are engineered, not guessed.
Inside, the working chamber carries high-brightness LED lighting, an LCD control panel and 10A splash-proof sockets; the body assembles knock-down for freight economy and installs through any doorway. The VAV variable air volume control system is an option for facilities that meter their air.
Key features
- 1.0mm cold-rolled steel body. epoxy powder coated inside and out; side and back panels integrally formed with shielded welds — knock-down assembly ships and installs anywhere
- 5mm anti-bet liner and baffle. chemical-resistant interior in three sections that sweeps floor, work zone and ceiling for uniform containment
- 5mm tempered glass sash. vertical rising panel on a synchronous belt counterweight — single-hand operation, cycle-tested before dispatch
- High-brightness LED lighting. vapor-tight chamber lighting with an LCD control panel and 10A splash-proof sockets
- Published exhaust volumes. 1036 / 1360 / 1684 m³/h at 1200 / 1500 / 1800mm, with duct spigot diameters matched to standard ductwork
- VAV option. variable air volume control matches exhaust to sash position for energy-conscious facilities
- ASHRAE 110 verification. face velocity mapped at multiple sash heights before dispatch; SEFA 1 construction throughout
Specifications
| Model series | T1 / T5 / T6 benchtop |
|---|---|
| Working widths | 1200mm · 1500mm · 1800mm (4 / 5 / 6 ft) |
| Overall dimensions | 1200/1500/1800 × 850 × 1650mm (upper cabinet); optional base cabinet 1200/1500/1800 × 790 × 700mm |
| Body | 1.0mm cold-rolled steel, epoxy powder coated |
| Liner | 5mm anti-bet board |
| Baffle | 5mm anti-bet board, three-section |
| Sash | 5mm tempered glass, vertical rising, synchronous belt counterweight |
| Lighting | High-brightness LED |
| Electrical | LCD control panel, 10A splash-proof sockets |
| Exhaust volume | 1036 m³/h (1200mm) · 1360.8 m³/h (1500mm) · 1684.8 m³/h (1800mm) |
| Face velocity | 0.4-0.6 m/s at the working opening |
| Worktop options | Ceramic / epoxy resin / physical-chemical board |
| Options | VAV control · PP sink · service fixtures · airflow monitor · sash alarm |
| Compliance | ASHRAE 110 · SEFA 1 · SEFA 8M · ANSI/AIHA Z9.5 |
Where you would install it
- General chemistry. reagent-scale synthesis, reaction monitoring and solvent handling under full capture
- Quality control. titrations, dissolution and wet-chemistry benches
- Teaching laboratories. demonstrations with full visibility and a lockable sash
- Sample preparation. weighing, dispensing and light digestion before instrumental analysis
Reviews