Laboratory catalog

Class II Type B2 Biosafety Cabinets

A Type B2 cabinet exhausts 100% of its air outdoors and returns none of it to the workspace, which is what makes it the compliant choice for volatile solvents, cytotoxic drug preparation and radionuclide work. It needs hard ducting and a correctly sized remote blower, so the room and the building services decide whether B2 is possible at all. Listed models cover 4 to 6 ft widths, NSF 49 listed and EN 12469 variants, and thimble or hard-duct connections.

  • 10Products
  • 0Direct categories
  • Technical support
Class II Type B2 Biosafety Cabinets Laboratory equipment
Popular guide

What to Include in a Laboratory Product Quote

Provide the manufacturer or model, quantity, required specifications, destination and requested delivery timing. Clear requirements help reduce delays and ensure that packaging…

Read article

Showing all 10 results

  • Class II Type B2 Biosafety Cabinets

    Baker BioChemGARD e3 B2

    SKU: BSC-P125

    Brand / manufacturer
    Baker
    Airflow
    100% exhaust
    Sizes
    4 and 6 ft
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    BHC Series B2

    SKU: BSC-P130

    Brand / manufacturer
    BHC
    Airflow
    100% exhaust
    Widths
    1000 / 1300 / 1600 mm
    Filtration
    HEPA supply and exhaust
    Reference CN¥15,180–18,300 / per unitCNY reference · Final price by quotation
  • Class II Type B2 Biosafety Cabinets

    BIOBASE Class II B2

    SKU: BSC-P132

    Brand / manufacturer
    BIOBASE
    Airflow
    100% exhaust
    External size
    1383×775×2250 mm (4 ft)
    Internal size
    1210×600×660 mm
    Reference US$3,900 / per unitUSD reference · Final price by quotation
  • Class II Type B2 Biosafety Cabinets

    BOXUN BSC-1060B2

    SKU: BSC-P129

    Brand / manufacturer
    BOXUN
    Airflow
    100% exhaust
    Width
    1060 mm
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    Esco Labculture B2

    SKU: BSC-P124

    Brand / manufacturer
    Esco
    Airflow
    100% exhaust
    Width
    4 ft
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    Haier HR40-IIB2

    SKU: BSC-P128

    Brand / manufacturer
    Haier
    Airflow
    100% exhaust
    Width
    4 ft
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    LICHEN LC-BSC-1600IIB2

    SKU: BSC-P131

    Brand / manufacturer
    LICHEN
    Airflow
    100% exhaust
    Width
    1600 mm
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    NuAire LabGard NU-560 B2

    SKU: BSC-P126

    Brand / manufacturer
    NuAire
    Airflow
    100% exhaust
    Sizes
    4 and 6 ft
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    NuAire NU-581 Cytotoxic B2

    SKU: BSC-P127

    Brand / manufacturer
    NuAire
    Airflow
    100% exhaust
    Application
    Cytotoxic / hazardous drugs
    Filtration
    HEPA supply and exhaust
    Price on request
  • Class II Type B2 Biosafety Cabinets

    Thermo Scientific 1300 Series B2

    SKU: BSC-P123

    Brand / manufacturer
    Thermo Scientific
    Airflow
    100% exhaust, no recirculation
    Sizes
    4 and 6 ft
    Filtration
    HEPA supply and exhaust
    Price on request

TECHNICAL DATA

Class II Type B2 Biosafety Cabinets Specifications & Technical Documentation

Select a product to view its specifications, available options and technical documents.

Class II Type B2 Biosafety Cabinets

BIOBASE Class II B2

View Product
Brand / manufacturer
BIOBASE
Airflow
100% exhaust
External size
1383×775×2250 mm (4 ft)
Internal size
1210×600×660 mm
Exhaust airflow
1320 m³/h (776 CFM)
HEPA
99.995% @ 0.12 µm, dual
Noise
NSF 49 ≤67 dB / EN 12469 ≤65 dB
Airflow class
Class II Type B2
Available sizes
4 ft / 1000 / 1300 / 1600 mm
Compliance
CE; NMPA on registered variants
Configuration
BSC-4FB2-NA (4 ft) · BSC-1000IIB2 (1000 mm) · BSC-1300IIB2 (1300 mm) · BSC-1600IIB2 (1600 mm) · BSC-1000IIB2 registered (1000 mm)

APPLICATIONS

Class II Type B2 Biosafety Cabinets Applications & Use Cases

Application-led selection for real laboratory workflows.

Confirm installation needs

Check utilities, ventilation, access and the physical footprint before ordering.

Reduce lifecycle downtime

Evaluate cleaning, preventive maintenance, consumables and service access.

PERFORMANCE & SELECTION

Size the process correctly

Match chamber or platform capacity to typical and peak batches without unnecessary oversizing.

  • Working capacity
  • Load and vessel dimensions
  • Daily throughput
Size the process correctly
CONFIGURATION & COMPATIBILITY

Compare control performance

Review the speed, temperature, uniformity and timer parameters that affect the process.

  • Operating range
  • Stability and uniformity
  • Programs and alarms
Compare control performance
IDENTIFICATION & TRACEABILITY

Clear Product Identification & Specification

Product names, model numbers, SKUs and option identifiers keep quotations, orders and internal records aligned.

  • Product and model identification
  • Option-specific SKU information
  • Consistent quotation specifications
PRODUCT IDENTIFICATIONClass II Type B2 Biosafety Cabinets
Catalog
Laboratory equipment
Products
10
Selection
Specification-led
QUALITY RECORDS

Traceable Supply & Quality Inspection

Documentation and inspection requirements are confirmed against the selected product and order.

  • Product identification records
  • Pre-delivery checks
  • Documents available on request
Traceable Supply & Quality Inspection
QUALITY STANDARDS

Choose the Right Class II Type B2 Biosafety Cabinets Specification

Compare the specifications that determine application fit and acceptance.

G—01

Capacity & throughput

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—02

Control performance

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—03

Installation

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
G—04

Maintenance

TYPICAL APPLICATION

Selection guidance for laboratory, quality and procurement teams.

QUALITY CHARACTERISTICSConfirm the exact requirement before ordering
WHY WORK WITH US

Why Choose Our Laboratory Supply Services

Reliable Product Quality

Defined specifications and order-level checks.

Complete Technical Documentation

Documents support selection and compliance.

Flexible Options

Configurations for bench, pilot and production needs.

Professional Technical Support

Guidance on specification and application matching.

Planned Supply Capabilities

Support for recurring and project orders.

Delivery Support

Shipping requirements reviewed for each order.

Contact Our Supply Team
OPTIONS & SPECIFICATIONS

Class II Type B2 Biosafety Cabinets Options & Specifications

Choose the format that suits your application, workload and handling requirements.

Capacity & throughput

Control performance

Installation

Maintenance

TypeCapacity / OptionMaterial / SpecificationSuitable ApplicationStorage / Handling
Capacity & throughputBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
Control performanceBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
InstallationBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
MaintenanceBy selected productProduct-specific configurationConfirm with our teamFollow product guidance
INSTALLATION, HANDLING & MAINTENANCE

Class II Type B2 Biosafety Cabinets Handling & Care Guide

Follow the product manual and site procedures for safe installation, use and maintenance.

  1. 01

    Check Product & Accessories

    Confirm model, options and supplied components.

  2. 02

    Review Product Documentation

    Read installation and safety instructions before use.

  3. 03

    Prepare the Working Environment

    Confirm space, utilities and operating conditions.

  4. 04

    Plan Routine Care

    Follow cleaning, inspection and maintenance guidance.

Class II Type B2 Biosafety Cabinets Handling & Care Guide
VIDEOS

Manufacturing & Quality Process

Category video library

Add category-specific video covers, titles, durations and video URLs in the Videos ACF section.

TECHNICAL RESOURCES

Related Articles & Technical Resources

October 29, 2026

What to Include in a Laboratory Product Quote

Read More
October 29, 2026

A Practical Guide to Laboratory Glassware

Read More
October 29, 2026

How to Choose a Benchtop Centrifuge

Read More
GET A QUOTATION

Request a Class II Type B2 Biosafety Cabinets Quotation

Tell us your required products, specifications and quantities. Our sales team will contact you with suitable supply options.